Fabrication and simulation of silicon nanogaps pH sensor as preliminary study for Retinol Binding Protein 4 (RBP4) detection

Authors

  • M. I. Hashim Faculty of Electronic Engineering & Technology, Universiti Malaysia Perlis, 02600 Arau, Perlis, Malaysia
  • M. N. M. Nuzaihan Institute of Nano Electronic Engineering, Universiti Malaysia Perlis, 01000 Kangar, Perlis, Malaysia
  • M. F. M. Fathil Institute of Nano Electronic Engineering (INEE), Universiti Malaysia Perlis (UniMAP), 01000 Kangar, Perlis, Malaysia.
  • M. Shaifullah A.S Institute of Nano Electronic Engineering (INEE), Universiti Malaysia Perlis (UniMAP), 01000 Kangar, Perlis, Malaysia.
  • C. Y. Chean Faculty of Electronic Engineering & Technology, Universiti Malaysia Perlis, 02600 Arau, Perlis, Malaysia
  • N. H. A. Halim Institute of Nano Electronic Engineering (INEE), Universiti Malaysia Perlis (UniMAP), 01000 Kangar, Perlis, Malaysia.
  • Z. Zailan Faculty of Electronic Engineering & Technology, Universiti Malaysia Perlis, 02600 Arau, Perlis, Malaysia
  • M. K. Md Arshad Institute of Nano Electronic Engineering, Universiti Malaysia Perlis, 01000 Kangar, Perlis, Malaysia and Faculty of Electronic Engineering & Technology, Universiti Malaysia Perlis, 02600 Arau, Perlis, Malaysia
  • M. Isa Institute of Nano Electronic Engineering (INEE), Universiti Malaysia Perlis (UniMAP), 01000 Kangar, Perlis, Malaysia.
  • Azhari A. W. Faculty of Civil Engineering and Technology, Universiti Malaysia Perlis, 02600, Jalan Kangar-Arau, Perlis Malaysia and Center of Excellence for Water Research and Environmental Sustainability Growth (WAREG), Universiti Malaysia Perlis
  • M. Syamsul Institute of Nano Optoelectronics Research and Technology, USM, 11900 Pulau Pinang, Malaysia and Faculty of Science and Engineering, Waseda University, Shinjuku, Tokyo 169-8555, Japan
  • Rozaimah A.T. Bandar Baharu District Health Office, 09800 Serdang, Kedah

DOI:

https://doi.org/10.58915/ijneam.v18i1.1684

Abstract

In this research, a silicon nanogap biosensor has the potential to play a significant role in the field of biosensors for detecting Retinol Binding Protein 4 (RBP4) molecules due to its unique nanostructure morphology, biocompatibility features, and electrical capabilities. Additionally, as preliminary research for RBP4, a silicon nanogap biosensor with unique molecular gate control for pH measurement was developed. Firstly, using conventional lithography followed by the Reactive-ion etching (RIE) technique, a nanofabrication approach was utilized to produce silicon nanogaps from silicon-on-insulator (SOI) wafers. The critical aspects contributing to the process and size reduction procedures were highlighted to achieve nanometer-scale size. The resulting silicon nanogaps, ranging from 100 nm to 200 nm, were fabricated precisely on the device. Secondly, pH level detection was performed using several types of standard aqueous pH buffer solutions (pH 6, pH 7, pH 12) to test the electrical response of the device. The sensitivity of the silicon nanogap pH sensor was 7.66 pS/pH (R² = 0.97), indicating that the device has a wide range of pH detecting capacity. This also includes the silicon nanogap biosensor validated by simulation, with the sensitivity obtained being 3.24 μA/e.cm² (R² = 0.98). The simulation of the sensitivity is based on the interface charge (Qf) that represents the concentration of RBP4. The results reveal that the silicon nanogap biosensor has excellent characteristics for detecting pH levels and RBP4 with outstanding sensitivity performance. In conclusion, this silicon nanogap biosensor can be used as a new electrical RBP4 biosensor for biomedical diagnostic applications in the future.

Keywords:

Silicon nanogaps, Diabetes mellitus, Retinol Binding Protein 4, Electrical detection, Interface charge

Downloads

Published

10-01-2025

How to Cite

[1]
M. I. Hashim, “Fabrication and simulation of silicon nanogaps pH sensor as preliminary study for Retinol Binding Protein 4 (RBP4) detection”, IJNeaM, vol. 18, no. 1, pp. 28–35, Jan. 2025.

Issue

Section

Articles